Uhlelo lokusebenza oluhlakaniphile; Ukusebenza okulula ngama-alamu abonwayo nawomsindo; Isixhumi esibonakalayo sesevisi/isondlo esinezinjongo eziningi; Iphrofayili: i-sodium concentration ne-UF curve.
I-W-T6008S iqinisekisa ukuphepha nokusebenza kahle ngesikhathi sokuhlanza, inqobo nje uma ukwelashwa kwe-dialysis okunethezekile, okungasebenzisa: I-HDF eku-inthanethi, i-HD kanye ne-HF eku-inthanethi.
I-HDF ye-inthanethi
Igumbi lebhalansi yevolumu evaliwe eyamukelwayo, isilawuli esinembile sokuqeda amanzi emzimbeni;I-ultrafiltration yokhiye owodwa wejubane eliphansi: ingasetha i-UF yejubane eliphansi, isikhathi sokusebenza se-UF esinesivinini esiphansi, ibuyele kusivinini esivamile se-UF ngokuzenzakalelayo ngemva kokubulawa; isekela i-UF ehlukanisiwe, ingashintsha isikhathi esikhishiwe kanye nevolumu ye-UF ngokuya ngemfuneko ngenkathi i-UF ihlukanisiwe.
Umsebenzi wokhiye we-dialyzer priming+
Ingasetha isikhathi sokuqala, ivolumu yokukhipha amanzi emzimbeni esetshenziswa ngempumelelo ukuze kuthuthukiswe umphumela wokuqala wemigqa yegazi kanye ne-dialyzer futhi kuthuthukiswe ukwanela kwe-dialysis.
Inqubo ehlakaniphile yokubulala amagciwane kanye nenqubo yokuhlanza
Kungavimbela ngempumelelo ukufakwa kwe-calcium namaprotheni epayipini lomshini, okungadingekile ukusebenzisa i-sodium hypochlorite ukukhipha amaprotheni agwema ukulimala kubasebenzi bezokwelapha ngesikhathi kusetshenziswa i-sodium hypochlorite.
Umsebenzi wokukhipha ukhiye owodwa
Ukusebenza okulula nokusebenzayo kokhiye owodwa wokudonsa amanzi, ukususa ngokuzenzakalelayo uketshezi olulahlwe ku-bloodline kanye ne-dialyzer ngemva kokwelashwa kwe-dialysis, okuvimbela uketshezi lwemfucumfucu ukuthi lungachitheki phansi lapho kudilizwa ipayipi, kugcina indawo yokwelapha ihlanzekile futhi yehlise izindleko zokuphatha nezokuthutha imfucuza yezokwelapha.
I-alamu yedivayisi ye-Hemodialysis ehlakaniphile
Irekhodi lomlando we-alamu kanye nokubulala amagciwane
Isikrini sokuthinta se-LCD esingu-15 amayintshi
Kt/V ukuhlolwa
Kwenziwe ngendlela oyifisayo ukulungiselelwa kwepharamitha yephrofayili ye-Sodium ne-UF ngokusekelwe esimweni sangempela sokwelashwa kweziguli, esilungele ukwelashwa komuntu siqu, iziguli zizozizwa zikhululeke kakhudlwana phakathi nokukhishwa kwe-dialysis futhi zehlise izehlakalo zokusabela okubi okuvamile.
| Usayizi nesisindo | |
| Usayizi | 380mmx400x1380mm (L*W*H) |
| Isisindo Esiphelele cishe. | 88KG |
| I-Gross Weight cishe. | cishe 100KG |
| Usayizi Wephakheji cishe. | 650×690×1581mm (L x W x H) |
| Ukunikezwa kwamandla kagesi | |
| I-AC220V, 50Hz/60Hz, 10A | |
| Amandla okokufaka | 1500W |
| Gcina ibhethri | Imizuzu engama-30 |
| Isimo sokusebenza | |
| Ingcindezi yokufaka amanzi | 0.1Mpa~0.6Mpa, 15P.SI~60P.SI |
| Izinga lokushisa lokufakwa kwamanzi | 5℃~30℃ |
| Izinga lokushisa lendawo yokusebenza | 10℃~30℃ kumswakama ohlobene ≦70% |
| Inani eliphakeme kakhulu lama-UF | |
| Ibanga lokugeleza | 0ml/h~4000ml/h |
| Isilinganiso sokulungiswa | 1ml |
| Ukunemba | ±30ml/h |
| Iphampu yegazi & nephampu yokufaka esikhundleni | |
| Ibanga lokugeleza kwephampu yegazi | 10ml/min~600ml/min (ububanzi: 8mm noma 6mm) |
| Ibanga lokugeleza kwephampu esikhundleni | 10ml/min~300ml/min (ububanzi 8mm noma 6mm) |
| Isilinganiso sokulungiswa | 0.1ml |
| Ukunemba | ±10ml noma u-10% wokufunda |
| Iphampu ye-Heparin | |
| Usayizi wesirinji | 20, 30, 50ml |
| Ibanga lokugeleza | 0ml/h~10ml/h |
| Isilinganiso sokulungiswa | 0.1ml |
| Ukunemba | ±5% |
| Isistimu yokuqapha nokusethwa kwe-alamu | |
| Ukucindezela kwe-venous | -180mmHg ~ +600mmHg, ±10mmHg |
| Umfutho wegazi | -380mmHg ~ +400mmHg, ±10mmHg |
| I-TMP | -180mmHg ~ +600mmHg, ±20mmHg |
| Izinga lokushisa le-Dialysate | ububanzi obusethiwe 34.0℃~39.0℃ |
| Ukugeleza kwe-Dialysate | Ngaphansi kuka-800 ml/min (Kuyalungiseka) |
| Ibanga lokugeleza lokushintsha | 0-28 L/H (ku-inthanethi HDF) |
| Ukutholwa kokuvuza kwegazi | I-alamu yesithombe se-chromic lapho ivolumu ethize ye-erythrocyte ingu-0.32±0.02 noma ivolumu yokuvuza kwegazi ilingana noma ingaphezu kuka-1ml ilitha ngalinye le-dialysate. |
| Ukutholwa kwebhamuza | I-Ultrasonic, i-alamu lapho ivolumu yebhamuza lomoya elilodwa ingaphezu kuka-200μl ekugelezeni kwegazi okungu-200ml/min. |
| I-Conductivity | I-Acoustic-optic |
| Ukubulala amagciwane/Ukuhlanza | |
| 1. Ukukhipha amagciwane okushisayo | |
| Isikhathi: imizuzu engu-30; Izinga lokushisa: mayelana 80 ℃, at flow rate 500ml/min; | |
| 2. Ukubulala amagciwane ngamakhemikhali | |
| Isikhathi: 30minutes, izinga lokushisa: mayelana 36 ℃ ~ 50 ℃, at flow rate 500ml/min; | |
| 3. Ukubulala amagciwane ngamakhemikhali ngokushisa | |
| Isikhathi: 45minutes, izinga lokushisa: mayelana 36 ℃ ~ 80 ℃, at flow rate 50ml/min; | |
| 4. Hlanza | |
| Isikhathi: 10minutes, Izinga lokushisa: mayelana 37 ℃, at flow rate 800ml/min; | |
| Indawo Yesitoreji | |
| Izinga lokushisa lesitoreji kufanele libe phakathi kuka-5℃~40℃, kumswakama ohlobene ≦80% | |
| Umsebenzi | |
| I-HDF, i-BPM eku-inthanethi, i-Bi-cart kanye nezihlungi ze-endotoxin zama-pcs ama-2 | |