Uhlelo lokusebenza oluhlakaniphile; Ukusebenza okulula ngama-alamu abonakalayo nawo alalelwayo; I-Multi-Inhloso Service / I-interface; Iphrofayili: Ukuhlushwa kwe-sodium kanye ne-uf curve.
I-W-T6008 iqinisekisa ukuphepha nokusebenza kahle ngesikhathi sokudaya dialysis, ihlinzeke ukwelashwa kwe-dialysis entofontofo, engayisebenzisa
On-line HDF
Ukulawulwa kwe-Volume Balance evaliwe, Ukulawulwa kwe-Ultrafiltration dehydration; i-Ult-Key ephansi yejubane eliphansi Ukusekelwa kwe-UF ehlukanisiwe, kungaguqula isikhathi esenziwe nge-UF kususelwa kwisidingo ngenkathi i-UF isolated.
Umsebenzi wokugcina we-dialyzer owodwa
Ingasetha isikhathi esifudumele, ivolumu yokumiswa kokuwohloka komzimba okusetshenziswa ngempumelelo kwe-deffision kanye ne-convection mechanism ukuze uthuthukise umphumela wokuqala we-bloodlines ne-dialyzer futhi uthuthukise i-dialysis ngokwanele.
I-Intelligent automatic disinfection kanye nenqubo yokuhlanza
Kungavimbela ngempumelelo ukubekwa kwe-calcium ne-protein epayipini yomshini, okungadingekile ukusebenzisa i-sodium hypochlorite ukususa amaprotheni avimbela ukulimala kwabasebenzi bezokwelapha.
Umsebenzi wokudonsa okhiye owodwa
Umsebenzi olula futhi osebenzayo wokudonsa amanzi, susa ngokuzenzakalelayo uketshezi lokungcola ku-gearyline kanye ne-dialyzer ngemuva kokwelashwa kwe-dialysis, okuvimbela ipayipi lokungcola kusuka ekuchithekeni phansi lapho kuvinjelwa indawo yokwelashwa ihlanzekile futhi inciphise izindleko zokuphatha imfucuza.
Uhlelo lwe-alamu ye-alamu ye-hemodialysis
Umlando Record of Alarm kanye Disinfection
I-15 inches LCD Touch Screen
Ukuhlolwa kwe-KT / V
Kwenziwe ngezifiso i-sodium kanye ne-uf profilerameter photilet ngokususelwa esimweni sangempela sokwelashwa kwangempela, okulungele ukwelashwa okwenziwe ngokomtholampilo, iziguli zizizwa zikhululekile ngokwengeziwe ngesikhathi sokudayiza futhi zinciphise izehlakalo zokuphendula okuhlukile.
Usayizi nesisindo | |
Ubungako | 380mmx400x1380mm (L * W * H) |
Isisindo se-net approx. | I-88kg |
Isisindo esikhulu. | cishe nge-100kg |
Iphakheji usayizi approx. | I-650 × 690 × 1581mm (l x w x h) |
Ukunikezwa kwamandla kagesi | |
AC220V, 50HZ / 60hz, 10a | |
Amandla okufaka | 1500w |
Ibhethri emuva emuva | Imizuzu engama-30 |
Isimo sokusebenza | |
Ingcindezi yokufaka yamanzi | 0.1MPA ~ 0.6MPA, 15p.si ~ 60p.si |
Izinga lokushisa lamanzi | 5 ℃ ~ 30 ℃ |
Ukusebenza Kwemvelo Yemvelo | I-10 ℃ ~ 30 ℃ ekudleni okuhlobene ≦ 70% |
Isilinganiso se-UF | |
Ububanzi bokuhamba | 0ml / h ~ 4000ml / h |
Isilinganiso sokuxazulula | I-1ml |
Ukwenza kahle | ± 30ml / h |
I-Blood Pump & Pumplether Pump | |
Ibanga lokugeleza kwephampu yegazi | I-10mL / Min ~ 600ml / min (ububanzi: 8mm noma i-6mm) |
Uhla lokuhamba ngePumplem Pump | I-10mL / Min ~ 300ml / Min (ububanzi 8mm noma i-6mm) |
Isilinganiso sokuxazulula | I-0.1ML |
Ukwenza kahle | ± 10ML noma i-10% yokufunda |
I-Heparin Pump | |
Usayizi wesirinji | 20, 30, 50ml |
Ububanzi bokuhamba | 0ml / h ~ 10ml / h |
Isilinganiso sokuxazulula | I-0.1ML |
Ukwenza kahle | ± 5% |
Uhlelo lokuqapha kanye nokusetha i-alamu | |
Ingcindezi ye-venous | -180mmhg ~ + 600mmhg, ± 10mmhg |
Ukucindezela kwe-Arterial | -380mmhg ~ + 400mmhg, ± 10mmhg |
I-TMP | -180mmhg ~ + 600mmhg, ± 20mmhg |
Ukushisa kwe-Dialysate | Ibanga lokusetha kabusha 34.0 ℃ ~ 39.0 ℃ |
Ukugeleza okudakayo | Ngaphansi kwama-800 ml / min (aguquguqukayo) |
Ibanga lokungena esikhundleni | 0-28 L / h (On line HDF) |
Ukutholwa Kwe-Blood Lack | I-Alarm ye-Photo Chromic lapho ivolumu ethile ye-Erythrocyte ingu-0.32 ± 0.02 |
Ukutholwa kwe-Bubble | I-Ultrasonic, i-alamu lapho ivolumu ye-bubble eyodwa yomoya ingaphezu kuka-200ml ku-200ML / ukugeleza kwegazi kwegazi |
Ukubangelanisa | Acoustic-optic |
I-Disinfection / Sanitize | |
1. Ukubulala amagciwane ashisayo | |
Isikhathi: imizuzu engama-30; Lokushisa: cishe ama-80 ℃, nge-flow rate 500ml / min; | |
2. I-Chemical Disninfection | |
Isikhathi: 30minutes, izinga lokushisa: cishe ama-36 ℃ ~ 50 ℃ ~ 50 ℃, nge-flow rate 500ml / min; | |
3. Ukubulala amagciwane anokushisa | |
Isikhathi: Ama-45minutes, izinga lokushisa: cishe ama-36 ℃ ~ 80 ℃, nge-flow rate 50ml / min; | |
4. Hlambulula | |
Isikhathi: 10minutes, izinga lokushisa: cishe ama-37 ℃, nge-flow rate 800ml / min; | |
Indawo Yendawo Yokugcina | |
Ukushisa kwesitoreji kufanele kube phakathi kwe-5 ℃ ~ 40 ~ 40, lapho umswakama ohlobene ≦ 80% | |
Sebenza | |
I-HDF, on-line BPM, I-BI-Cart kanye nama-2 PCS Endotoxin Ukuhlunga |