izindaba

izindaba

I-W-F168-B Umshini Wokucubungula Kabusha Umshini Wokucubungula Isicelo Somtholampilo

Okuqukethwe yi-reprort yemagazini:
- Kucashunwe kuJournal of Biomedical Engineering, Juni 2009
Yang Lichuan, Zheng Yujun, Deng Zhengxu, Fu Ping, Chen Lin

Qaphela umthelela wokusetshenziswa komtholampilo womshini wokuphinda usebenzise isidayalyza se-W-F168-B okhiqizwe yi-Chengdu Weisheng Biological Materials Company, qonda umthelela wawo kungqikithi yevolumu yeseli (TCV) ye-dialyzer nokwanela kwe-dialysis kwezihloko, futhi uhlole umphumela wawo wokubulala amagciwane. Izihloko ezihlangabezane nemibandela yokufakwa zahlukaniswa ngokungahleliwe zaba amaqembu amabili. Ama-dialyzer eqenjini lokuhlola kanye neqembu lokulawula aphinde asetshenziswa ne-W-F168-B kanye ne-RENATRON II (ekhiqizwe i-Mintech e-United States), ngokulandelanayo. Hlola i-TCV ye-dialyzer ngaphambi nangemuva kokuphinda uyisebenzise, ​​bala izinga lokusulwa kwe-urea lezihloko ezihlukaniswa ngevolumu yokusabalalisa (Kt/V, lapho u-K iyinani lokususa i-urea, t isikhathi sokudayela, futhi V ivolumu yokusabalalisa) , futhi iqoqe amasampula egazi ezihlokweni ngemva kokukhishwa kwe-dialysis ukuze kutshalwe amagciwane. Imiphumela yavezwa njengokuchezuka okushiwo ± okujwayelekile, kusetshenziswa ukuhlolwa kwe-t ngedizayini yeqembu, futhi yahlaziywa kusetshenziswa iphakheji yesofthiwe yezibalo ye-SPSS 13.0. Umehluko ku-TCV phakathi kweqembu lokuhlola kanye neqembu lokulawula ngaphambi nangemva kokusetshenziswa kabusha kwakuyi-5.5 ± 4.15, 4.5 ± 2.56, ne-P0.05, ngokulandelana; Amanani e-Kt/V abengu-1.25 ± 0.26, 1.24 ± 0.19, kanye no-P0.05, ngokulandelana, futhi imiphumela yokuhlolwa kwe-t ayizange ibonise umehluko wezibalo. Akukho ukukhula kwebhaktheriya noma ukukhunta okwabonwa esikweni legazi. Imiphumela yokuhlola ibonisa ukuthi awukho umehluko ophawulekayo kumthelela wezinhlobo ezimbili zemishini yokusetshenziswa kabusha kwe-dialyzer ekusebenzeni kwe-dialyzer kanye nomthelela we-dialyzer esetshenziswe kabusha ekwaneleni kwe-dialysis kwezihloko, ezingafinyelela ikhwalithi enhle ye-dialysis.

[Qaphela] Iyunithi yombhali: Department of Nephrology, West China Hospital, Sichuan University.

Okuthunyelwe kwangaphambilini :Usihlalo, njll. waseTaiwan Lienchang Group, weza e-Weilisheng ukuze uthole ukubonisana kwebhizinisi lezesekeli ze-elekthronikhi.
Okuthunyelwe okulandelayo: Usihlalo, njll. waseTaiwan Lienchang Group, weza e-Weilisheng ukuze uthole ukubonisana kwebhizinisi lezesekeli ze-elekthronikhi.


Isikhathi sokuthumela: Jun-28-2010